[CentOS] MegaCli 설치 및 활용(H700 Auto Learn Cycle : Disable) Server



# RAID Controller device 확인


[root@localhost ~]# lspci -v |grep LSI
03:00.0 RAID bus controller: LSI Logic / Symbios Logic LSI MegaSAS 9260 (rev 05)


# MegaCli 설치(srvadmin-storelib와 충돌나기에 강제로 설치)
Download : http://www.lsi.com/products/storagecomponents/Pages/MegaRAIDSAS9260-8i.aspx



[root@localhost ~]# rpm -ivh --nodeps --force Lib_Utils-1.00-09.noarch.rpm
Preparing...                ########################################### [100%]
Installing....
   1:Lib_Utils              ########################################### [100%]



[root@localhost ~]# rpm -ivh MegaCli-8.02.21-1.noarch.rpm
Preparing...                ########################################### [100%]
   1:MegaCli                ########################################### [100%]


# MegaCli로 컨트롤러 세부정보 확인

[root@localhost ~]# /opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL
                                    
Adapter #0

==============================================================================
                    Versions
                ================
Product Name    : PERC H700 Integrated
Serial No       : 16301CS
FW Package Build: 12.10.2-0004

                    Mfg. Data
                ================
Mfg. Date       : 06/11/11
Rework Date     : 06/11/11
Revision No     : A04
Battery FRU     : N/A

                Image Versions in Flash:
                ================
BIOS Version       : 3.18.00_4.09.05.00_0x0416A000
FW Version         : 2.100.03-1405
Preboot CLI Version: 04.04-010:#008
Ctrl-R Version     : 2.02-0025.1
NVDATA Version     : 2.07.03-0003
Boot Block Version : 2.02.00.00-0000
BOOT Version       : 01.250.04.219

                Pending Images in Flash
                ================
None

:
:
:
:
:

Exit Code: 0x00





# MegaCli로 컨트롤러 간단정보 확인 


[root@localhost ~]# /opt/MegaRAID/MegaCli/MegaCli64 -ShowSummary -aALL
                                    
System
        Operating System:  Linux version 2.6.18-238.el5
        Driver Version: 00.00.04.31-RH1
        CLI Version: 8.02.21

Hardware
        Controller
                 ProductName       : PERC H700 Integrated(Bus 0, Dev 0)
                 SAS Address       : 5782bcb044716f00
                 FW Package Version: 12.10.2-0004
                 Status            : Need Attention
        BBU
                 BBU Type          : BBU
                 Status            : Pack Missing
        Enclosure
                 Product Id        : BACKPLANE     
                 Type              : SES
                 Status            : OK

        PD
                Connector          : 00<Internal><Encl Pos 0 >: Slot 0
                Vendor Id          : ATA   
                Product Id         : FUJITSU MHZ2250B
                State              : Online
                Disk Type          : SATA,Hard Disk Device
                Capacity           : 232.375 GB
                Power State        : Active

                Connector          : 00<Internal><Encl Pos 0 >: Slot 2
                Vendor Id          : ATA   
                Product Id         : TOSHIBA MK2561GS
                State              : Online
                Disk Type          : SATA,Hard Disk Device
                Capacity           : 232.375 GB
                Power State        : Active

                Connector          : 00<Internal><Encl Pos 0 >: Slot 3
                Vendor Id          : ATA   
                Product Id         : TOSHIBA MK2561GS
                State              : Unconfigured Good
                Disk Type          : SATA,Hard Disk Device
                Capacity           : 232.375 GB
                Power State        : Active

Storage

       Virtual Drives
                Virtual drive      : Target Id 0 ,VD name Virtual Disk 0
                Size               : 232.375 GB
                State              : Optimal
                RAID Level         : 0

                Virtual drive      : Target Id 1 ,VD name Virtual Disk 1
                Size               : 232.375 GB
                State              : Optimal
                RAID Level         : 0


Exit Code: 0x00




# Load Balance Mode 확인


[root@localhost ~]# /opt/MegaRAID/MegaCli/MegaCli64 -AdpGetProp -LoadBalanceMode -a0
                                    
Adapter 0: Load Balance Mode: Auto

Exit Code: 0x00




# Learn Cycle Disable 설정


[root@localhost ~]# vi h700_bbu_autolearn.sh
#!/bin/sh
TMPFILE=$(mktemp -p /tmp bbu.relearn.off.XXXXXXXXXX) || exit 1
echo "autoLearnMode=1" > $TMPFILE # or =0 to enable the bbu relearn
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -SetBbuProperties -f$TMPFILE -a0
rm -f $TMPFILE


[root@localhost ~]# ./h700_bbu_autolearn.sh
                                    
Adapter 0: Set BBU Properties Succeeded.

Exit Code: 0x00



# Learn Cycle Disable 확인

[root@localhost ~]# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuProperties -a0
                                    

BBU Properties for Adapter: 0

Auto Learn Period: 7776000 Sec
Next Learn time: 395069866 Sec
Learn Delay Interval:0 Hours
Auto-Learn Mode: Disabled

Exit Code: 0x00



[root@localhost ~]# /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuProperties -a0 | grep "Auto-Learn Mode: Disabled"
Auto-Learn Mode: Disabled




# cron job 설정
    : off-peak time에 crontable 설정하여 learn을 강제로 start 시킴